SHIMADZU UV-1700
Á¦Á¶»ç : SHIMADZU
»óÇ°À̸§ : UV-1700
ÆǸŰ¡ : º°µµ¹®ÀÇ
Ä«Å×°í¸® : ºÐ±¤±¤µµ°è
Àç°í»óÅ : Àç°í ÀÖÀ½
      

»óÇ°Á¤º¸  

 



UV-1700 PharmaSpec ´Â ,FDA¹× ¾à±¹¹æÀÌ ¿ä±¸ÇÏ´Â »ç¾çÀ̳ª ±â´ÉÀ» Áß½ÃÇØ °³¹ßÇÑ Áß±Þ »óÀ§ Ŭ·¡½ºÀÇ ÀÚ¿Ü °¡½Ã ºÐ±¤ ±¤µµ°èÀÔ´Ï´Ù.

±â¾÷°£ÀÇ ±Û·Î¹ú °æÀïÀÌ °Ý·ÄÇÔÀ» ´Ã¸®´Â ¿À´Ã , ½Å¾àÀ̳ª À¯ÀüÀÚ Á¶ÀÛ ½ÄÇ°µîÀÇ ¿¬±¸¡¤°³¹ßÀÌ ±Þ¼ÓÈ÷ ÁøÇàµÇ´Â ÇÑÆíÀ¸·Î , ±×·¯ÇÑ Á¦Ç°ÀÇ ¡¸¾ÈÀü¼º¡¹À̳ª ¡¸ÃøÁ¤ °á°úÀÇ Á¤È®ÇÔ¡¹¿¡ ´ëÇÑ ¿ä±¸µµ ´õ¿í ´õ ¾î·Á¿òÀ» ´Ã¸®°í ÀÖ½À´Ï´Ù.
Çϵå¿þ¾îÀÇ °³·®¿¡ ÀÇÇØ , Áß±Þ »óÀ§ Ŭ·¡½º¿¡¼­ , ¼¼°è ÃÖ°í ·¹º§ÀÇ ÆÄÀå ºÐÇØ1nm(º»Å¬·¡½º Á¾·¡±â°èÁ¾ÀÇ2¹èÀÇ ºÐÇØ°¡´É) ¸¦ ½ÇÇöÇÏ°í ÀÖ½À´Ï´Ù. ÀÌ°Í¿¡ ÀÇÇØ À¯·´¡¤¹Ì±¹¡¤ÀϺ»ÀÇ ¾à±¹¹æÀÌ ¿ä±¸ÇÏ´Â »ç¾ç¿¡ ÁØ°ÅÇÔ°ú ÇÔ²² , ¿¬±¸°³¹ß¡¤Ç°Áú°ü¸®¿¡ ºÒ°¡°áÇÑ ¹Ù¸®µ¥À̼ÇÀ» È®½ÇÈ÷ ½Ç½ÃÇÒ ¼ö ÀÖ°Ô µÇ¾ú½À´Ï´Ù.


¹Ù¸®µ¥ÀÌ¼Ç ±â´ÉÀ» Ç¥ÁØ Àåºñ
ÀÚµ¿ ¹Ù¸®µ¥ÀÌ¼Ç ±â´ÉÀ» Ç¥ÁØ Àåºñ ÇØ , ¿¬±¸°³¹ß¡¤Ç°Áú°ü¸®¿¡ ºÒ°¡°áÇÑ ¹Ù¸®µ¥À̼ÇÀ» È®½ÇÈ÷ ½Ç½ÃÇÒ ¼ö ÀÖ½À´Ï´Ù.
¡¡ÀÚµ¿ ¹Ù¸®µ¥ÀÌ¼Ç Ç׸ñ£ºÆÄÀå Á¤È®ÇÔ , ÆÄÀå ¼³Á¤ ¹Ýº¹ Á¤¹Ðµµ , ºÐÇØ , baseline Æòźµµ , baseline ¾ÈÁ¤µµ , ³ëÀÌÁî ·¹º§ , Ãø±¤ Á¤È®ÇÔ , Ãø±¤ ¹Ýº¹ Á¤¹Ðµµ , ¹Ì±¤

IQ/OQ,GLP/GMP¿¡ ´ëÀÀ
ÀåÄ¡ÀÇ ÀûÇÕ ¼±¾ð¼­³ª °Ë»ç ¼ºÀû¼­¿¡ °¡¼¼ÇØIQ/OQ¼³Ä¡ ¼­Æ÷Æ®¸¦ À§ÇÑ °¢Á¾ ¹®¼­ ¹× ÀåÄ¡ÀÇ Á¤±â Á¡°Ëµî ¿¡ »ç¿ëÇÒ ¼ö ÀÖ´Â ¼ø¼­¼­³ª ¼ºÀû¼­¸¦ ÁغñÇß½À´Ï´Ù. ±×¸®°í , ¿öÅ©½ºÅ×ÀÌ¼Ç ¼ÒÇÁÆ®¿þ¾î ¡¸
UVProbe¡¹(¿É¼Ç) À» »ç¿ëÇϸé ,GLP/GMP´ëÀÀ¿¡ ºÒ°¡°áÇÑ ¿ÀµðƮƮ·¹ÀÏ ±â´É¡¤½ÃÅ¥·¯Æ¼ ±â´É¡¤µ¥ÀÌÅÍ ÀÎÅױ׸®Æ¼ ±â´ÉÀÌ ÀÌ¿ë °¡´ÉÇØÁý´Ï´Ù

Spectrophotometer Specifications (UV-1700)
Item Specification
Spectra l bandwidth 1 nm (190 to 900 nm)
Dimensions 550W x 470D x 200 H (mm) (max. height 380 mm)
Weight 17 kg
Wavelength range 190.0 to 1100.0 nm
Wavelength display 0.1 nm increments
Wavelength setting 0.1 nm increments (1 nm increments when setting scan range)
Wavelength accuracy ¡¾0.3 nm
Wavelength repeatability ¡¾0.1 nm.
Wavelength Scan Rates Wavelength slew speed: Approx. 6000 nm/min
Wavelength scanning speed: Approx. 3000 nm/min to 10 nm/min
Lamp interchange wavelength 295.0 nm to 364.0 nm (340.8 nm)
Stray light 0.04% max. (220.0 nm NaI, 340.0 nm NaNO2)
Photometric system Double-beam Optics
Photometric range Absorbance: -0.5 to +3.0 Abs
Transmittance: 0.0 to 300%
Recording range Absorbance: -3.99 to +3.99 Abs
Transmittance: -399 to +399%
Photometric accuracy

¡¾0.004 Abs (at 1.0 Abs), using NIST930D filter
¡¾0.002 Abs (at 0.5 Abs)

Photometric repeatability

¡¾0.002 Abs (at 1.0 Abs)
¡¾0.001 Abs (at 0.5 Abs)

Baseline stability 0.001 Abs/h max (700 nm, After 1hour from power on)
Baseline flatness

¡¾0.001 Abs (1100 mm to 200 mm) After 1hour from power on

Noise level 0.002 Abs (P-P) 0.0002 A (RMS) (700nm)
Baseline correction Automatic with computer memory, in two stages of coarse and fine
Light source 20 W halogen lamp, deuterium lamp Built-in light source automatic position adjustment
Monochromator Aberration-corrected blazed holographic grating
Detector Silicone photodiode
Sample compartment Internal dimensions: 110.0W x 230.0D x 105.0H (mm)
Distance between light beams: 100.00 mm
Installation: Fixed with two screws
Beam size: 9 x 0.5 mm
Power requirements 100, 120, 220, 240 VAC
50/60 Hz, 130 VA
Ambient requirements Temperature: 15 to 35¡ÆC, humidity: 35 to 80%

 