±â¾÷°£ÀÇ ±Û·Î¹ú °æÀïÀÌ °Ý·ÄÇÔÀ» ´Ã¸®´Â ¿À´Ã , ½Å¾àÀ̳ª À¯ÀüÀÚ Á¶ÀÛ ½ÄÇ°µîÀÇ ¿¬±¸¡¤°³¹ßÀÌ ±Þ¼ÓÈ÷ ÁøÇàµÇ´Â ÇÑÆíÀ¸·Î , ±×·¯ÇÑ Á¦Ç°ÀÇ ¡¸¾ÈÀü¼º¡¹À̳ª ¡¸ÃøÁ¤ °á°úÀÇ Á¤È®ÇÔ¡¹¿¡ ´ëÇÑ ¿ä±¸µµ ´õ¿í ´õ ¾î·Á¿òÀ» ´Ã¸®°í ÀÖ½À´Ï´Ù. Çϵå¿þ¾îÀÇ °³·®¿¡ ÀÇÇØ , Áß±Þ »óÀ§ Ŭ·¡½º¿¡¼ , ¼¼°è ÃÖ°í ·¹º§ÀÇ ÆÄÀå ºÐÇØ1nm(º»Å¬·¡½º Á¾·¡±â°èÁ¾ÀÇ2¹èÀÇ ºÐÇØ°¡´É) ¸¦ ½ÇÇöÇÏ°í ÀÖ½À´Ï´Ù. ÀÌ°Í¿¡ ÀÇÇØ À¯·´¡¤¹Ì±¹¡¤ÀϺ»ÀÇ ¾à±¹¹æÀÌ ¿ä±¸ÇÏ´Â »ç¾ç¿¡ ÁØ°ÅÇÔ°ú ÇÔ²² , ¿¬±¸°³¹ß¡¤Ç°Áú°ü¸®¿¡ ºÒ°¡°áÇÑ ¹Ù¸®µ¥À̼ÇÀ» È®½ÇÈ÷ ½Ç½ÃÇÒ ¼ö ÀÖ°Ô µÇ¾ú½À´Ï´Ù.
¹Ù¸®µ¥ÀÌ¼Ç ±â´ÉÀ» Ç¥ÁØ Àåºñ ÀÚµ¿ ¹Ù¸®µ¥ÀÌ¼Ç ±â´ÉÀ» Ç¥ÁØ Àåºñ ÇØ , ¿¬±¸°³¹ß¡¤Ç°Áú°ü¸®¿¡ ºÒ°¡°áÇÑ ¹Ù¸®µ¥À̼ÇÀ» È®½ÇÈ÷ ½Ç½ÃÇÒ ¼ö ÀÖ½À´Ï´Ù. ¡¡ÀÚµ¿ ¹Ù¸®µ¥ÀÌ¼Ç Ç׸ñ£ºÆÄÀå Á¤È®ÇÔ , ÆÄÀå ¼³Á¤ ¹Ýº¹ Á¤¹Ðµµ , ºÐÇØ , baseline Æòźµµ , baseline ¾ÈÁ¤µµ , ³ëÀÌÁî ·¹º§ , Ãø±¤ Á¤È®ÇÔ , Ãø±¤ ¹Ýº¹ Á¤¹Ðµµ , ¹Ì±¤
IQ/OQ,GLP/GMP¿¡ ´ëÀÀ ÀåÄ¡ÀÇ ÀûÇÕ ¼±¾ð¼³ª °Ë»ç ¼ºÀû¼¿¡ °¡¼¼ÇØIQ/OQ¼³Ä¡ ¼Æ÷Æ®¸¦ À§ÇÑ °¢Á¾ ¹®¼ ¹× ÀåÄ¡ÀÇ Á¤±â Á¡°Ëµî ¿¡ »ç¿ëÇÒ ¼ö ÀÖ´Â ¼ø¼¼³ª ¼ºÀû¼¸¦ ÁغñÇß½À´Ï´Ù. ±×¸®°í , ¿öÅ©½ºÅ×ÀÌ¼Ç ¼ÒÇÁÆ®¿þ¾î ¡¸UVProbe¡¹(¿É¼Ç) À» »ç¿ëÇϸé ,GLP/GMP´ëÀÀ¿¡ ºÒ°¡°áÇÑ ¿ÀµðƮƮ·¹ÀÏ ±â´É¡¤½ÃÅ¥·¯Æ¼ ±â´É¡¤µ¥ÀÌÅÍ ÀÎÅױ׸®Æ¼ ±â´ÉÀÌ ÀÌ¿ë °¡´ÉÇØÁý´Ï´Ù
Spectrophotometer Specifications (UV-1700) |
Item |
Specification |
Spectra l bandwidth |
1 nm (190 to 900 nm) |
Dimensions |
550W x 470D x 200 H (mm) (max. height 380 mm) |
Weight |
17 kg |
Wavelength range |
190.0 to 1100.0 nm |
Wavelength display |
0.1 nm increments |
Wavelength setting |
0.1 nm increments (1 nm increments when setting scan range) |
Wavelength accuracy |
¡¾0.3 nm |
Wavelength repeatability |
¡¾0.1 nm. |
Wavelength Scan Rates |
Wavelength slew speed: Approx. 6000 nm/min Wavelength scanning speed: Approx. 3000 nm/min to 10 nm/min |
Lamp interchange wavelength |
295.0 nm to 364.0 nm (340.8 nm) |
Stray light |
0.04% max. (220.0 nm NaI, 340.0 nm NaNO2) |
Photometric system |
Double-beam Optics |
Photometric range |
Absorbance: -0.5 to +3.0 Abs Transmittance: 0.0 to 300% |
Recording range |
Absorbance: -3.99 to +3.99 Abs Transmittance: -399 to +399% |
Photometric accuracy |
¡¾0.004 Abs (at 1.0 Abs), using NIST930D filter ¡¾0.002 Abs (at 0.5 Abs) |
Photometric repeatability |
¡¾0.002 Abs (at 1.0 Abs) ¡¾0.001 Abs (at 0.5 Abs) |
Baseline stability |
0.001 Abs/h max (700 nm, After 1hour from power on) |
Baseline flatness |
¡¾0.001 Abs (1100 mm to 200 mm) After 1hour from power on |
Noise level |
0.002 Abs (P-P) 0.0002 A (RMS) (700nm) |
Baseline correction |
Automatic with computer memory, in two stages of coarse and fine |
Light source |
20 W halogen lamp, deuterium lamp Built-in light source automatic position adjustment |
Monochromator |
Aberration-corrected blazed holographic grating |
Detector |
Silicone photodiode |
Sample compartment |
Internal dimensions: 110.0W x 230.0D x 105.0H (mm) Distance between light beams: 100.00 mm Installation: Fixed with two screws Beam size: 9 x 0.5 mm |
Power requirements |
100, 120, 220, 240 VAC 50/60 Hz, 130 VA |
Ambient requirements |
Temperature: 15 to 35¡ÆC, humidity: 35 to 80% |
|