Ä£Àý¡¤½ÉÇà ¼³°èÀÇ ¿øÀÚ Èí±¤ ±¤µµ°è¡¡¡¡AA-6200
AA-6200(Àº)´Â , ´õºí ºö Ãø±¤ ¹æ½ÄÀÇ ±¤Çаè¿ÍD2¹ý(Áß¼ö¼Ò ·¥ÇÁ¹ý)¿¡ µû¸£´Â ¹é±×¶ó¿îµå º¸Á¤¹ýÀ» Ç¥ÁØ Àåºñ ÇÑ , ¡¸Àú°¡°Ý¡¹, ¡¸¼¼°è ÃÖ¼Ò¡¹ÀÇPCÁ¦¾î ÇÁ·¹ÀÓ ¿øÀÚ Èí±¤ ºÐ±¤ ±¤µµ°è.
°¡·ÎÆø ºÒ°ú27ÀÎÄ¡ , ¼¼°è ÃÖ¼Ò ·¹º§ÀÇ ÄÄÆÑÆ®ÇÑ º¸µð¸¦ °¡Áö´ÂAA-6200Àº °í¼º´ÉÀÇ ´õºí ºö ±¤Çа迡 ÀÇÇØ Àå½Ã°£ ¾ÈÁ¤µÈ baseline¸¦ Á¦°øÇÕ´Ï´Ù. ´õ¿í ,D2¹é±×¶ó¿îµå º¸Á¤ ±â´É Ç¥ÁØ Å¾À糪 ÀÚµ¿ ÆÄÀå ¼³Á¤ µî »ó±Þ±â¿¡ µÚ¶³¾îÁöÁö ¾Ê´Â ¼ö¸¹Àº ±â´Éµµ °¡µæÇÏ°í ÀÖ½À´Ï´Ù. °Ô´Ù°¡ À§Àúµå¿¡ µû¶ó Á¶ÀÛÀ» ÇÏ´Â °Í¸¸À¸·Î , ¼÷·ÃÀÚ¿Í °°Àº ·¹º§ÀÇ ÃøÁ¤ÀÌ °¡´ÉÇØÁö´Â ¼ÒÇÁÆ®¿þ¾î¡°WizAArd¡±À» žÀçÇÏ°í ÀÖ½À´Ï´Ù.
£¼Æ¯Â¡£¾ ¡Ü°£´Ü , Ä£Àý ¼³°èµÈ ¼ÒÇÁÆ®¿þ¾î¡°WizAArd¡± ¿ÀÆÛ·¹ÀÌ¼Ç ¼ÒÇÁÆ®¿þ¾î¡°WizAArd¡±ÀÇ ÃøÁ¤ ÆĶó¹ÌÅÍ ¼³Á¤ À§Àúµå¿¡ ÀÇÇØ , óÀ½ ¿øÀÚ Èí±¤ ºÐ±¤ ±¤µµ°è°¡ Á¶À۵Ǵ (ºÐ)Æí¿¡¼µµ , ±×¸®°í Á¾·¡ÀÇ standalone ÀåÄ¡°¡ »ç¿ëµÇ°í ÀÖ´Â À¯Àú¶óµµ , ¿ëÀÌÇÏ°Ô ÃøÁ¤ ȯ°æÀ» ÀÛ¼ºÇÒ ¼ö ÀÖµµ·Ï(µíÀÌ) ¹è·ÁµÇ°í ÀÖ½À´Ï´Ù.
¡Ü°íÈ¿À² ±¤ÇÐ ¼³°è AA-6200ÀÇ ±¤Çаè´Â ´õºí ºö ±¤ÇаèÀÔ´Ï´Ù. ºöÄܹÙÀ̳ªºÎ¿¡´Â ÃÝÆÛ ¹Ð·¯ ¹æ½ÄÀ» ä¿ëÇÏ°í ÀÖ½À´Ï´Ù. Á¾·¡ÀÇ ¹ÝÅõ¸í°æ¿¡ ÀÇÇÏ´Â °Í¿¡ ºñÇØ ±¤·®ÀÇ ·Î½º°¡ ¾ø°í , ¾çÈ£ÇÑS/Nºñ¸¦ ¾òÀ» ¼ö ÀÖ½À´Ï´Ù.
¡Ü½ÃÄö¼ÈÀÎ ÀÚµ¿ ºÐ¼® °¡´É ¿ÀÆ®»êÇÁ¶óASC-6100°ú Á¶ÇÕÇÏ´Â °ÍÀ¸·Î , ÃÖ´ë60»ùÇÃÀÇ ´Ü¿ø¼Ò ÀÚµ¿ ºÐ¼®ÀÌ °¡´ÉÇØÁ® , ´ëÆøÀûÀÎ Àý·ÂÈ À» ÇÒ ¼ö°¡ ÀÖ½À´Ï´Ù.
¡Ü¾ÈÀü ´ëÃ¥µµ ¸¸Àü ¿¡¾î ÆÛÁö¿¡ ÀÇÇÑ ¾ÈÀü Á¡È¡¤¼ÒÈ , °¡½º¾Ð ¸ð´ÏÅÍ¿¡ ÀÇÇÑ ¿ªÈÀç ¿¹¹æÁö , ÇÁ·¹ÀÓ ¸ð´ÏÅÍ¿¡ ÀÇÇÑ ºÒ±æ ¼ »ç¶óÁö°í ¹æÁö , ¹ö³Ê¿À »ç¿ë ¹æÁö , Á¤Àü½Ã ÀÚµ¿ ¼ÒÈ , µî ¾ÈÀüÀ» À§ÇÑ ¸ð´ÏÅÍ ±â´ÉÀÌ °¡µæÇÕ´Ï´Ù. ¾È½ÉÇØ »ç¿ëÇØ ÁÖ¼¼¿ä.
Atomic Absorption Spectrophotometer AA-6200 |
Optics |
Double Beam (chopper mirror) |
Monochromator |
aberration corrected Czerny-Turner monochromator |
Holographic grating (1,600 lines/mm) |
Wavelength range |
190-900 nm |
Automated wavelength selection |
Slit |
0.2nm, 0.7 nm Manual setting |
Background Correction |
D2-Lamp method |
Lamp Turret |
2-lamps simultaneously lit (manual turret) |
Lamp Mode |
Emission, Non-BGC, BGC-D2 |
Frequency |
100Hz |
Nebulizer |
Nebulizer integrated impact bead and jacket tip |
Pt/Ir capillary |
Chamber |
Polypropylene |
Burner |
Fixed back/forward position and burner height |
(Simply switching of Air/C2H2 and N2O/ C2H2 burner) |
Titanium 10cm slot burner (Optional high temperature burner) |
Gas Control |
Manual setting of flow rate |
Automatic Air/ N2O switching system |
Safety |
Gas pressure monitoring to prevent flashback |
Automatic flame monitoring |
Safety interlock for misuse of burner |
Automatic flame extinguish when power failure |
Ignition |
Push ignite button |
Software |
Software based on MS-Windows!" |
Dimension and weight |
W690 x D425 x H370 mm, 38 kg |
Power requirements |
AC220V, 230V, 50/60Hz, 300 VA |
(Requires transformer for AC115V) |
(Certification of CE marking) |
Ambient temperature and humidity range |
Temperature: 10~35¡ÆC Humidity: 45~80% (but less than 70% if temperature is over 30¡ÆC |
Standard accessories |
Burner Head of 10cm slot. Nebulizer assembly. Deuterium lamp. Drain tube PTFE tube for sample suction. Hose assembly for Air. Hose assembly for C2H2. Hose band RS-232C connection cable (9P-9P). AC cable for 220, 230V |
Personal Computer requirements |
Operating environment: MS-WindowsTM 95 or MS-WindowsTM Ver3.1 |
CPU: 486DX-66 or Higher (In case of MS-WindowsTM3.1), Pentium-75 or Higher (In case of MS-WindowsTM 95) |
RAM: 16MB or higher |
CRT: VGA or Higher |
Hard disk: 120 Mb or larger |